| Released | Version | Details |
|---|---|---|
| 3/9/2024 | 7.2.3.127 | Firmware download integrity checks. Remote updates more robust with new failsafes introduced. |
| Display dimming reduced. | ||
| Repeaters rebalance at 7:30am, lineAmps rebalance at 7:00am (local time). 3 day reboot happens at 3am. | ||
| 16/3/2024 | 7.3.2.103 | PortSense feature added. Auto check all cables and connectors. Titan only. |
| signal reporting to allow StellaControl to display 4-LED and 6-LED indicators | ||
| Alerts now get plotted on the device history immediatly when they occur (before there was up to a 10 min delay) | ||
| Turn on/off Port Sense LEDs remotely. Titan only. | ||
| Rebal and Reboot synced to 3am, local time. fixed bug | ||
| Perform SHA256 checksum validation of downloaded firmware before passing to bootloader. | ||
| Blue uplink LED on LCD changed to a Square | ||
| Rebalance at 0700, Reboot at 0300 (local time) | ||
| Single LED status for LED Titans. Flashing means “trying to connect” , solid means “connected to platform” | ||
| 10/12/2023 | 7.3.1.x | PortSense feature added. Auto check all cables and connectors. |
| Telit embedded modem autoconnect. | ||
| Feedback detection further enhanced.(uplink feedback now much more robust) | ||
| New simple LED bank added(No need for LCD on iR4-T) | ||
| False uplink oscillations fixed. | ||
| Continous uplink alert now more reliable. | ||
| 25/8/2023 | 7.2.3.117 | 4 new metrics, Peak AGC, Peak Fast UL AGC, Peak uplink power, Peak downlink power. |
| Automatic shutdown (ASD) boolean variable added to message to more easily distinguish when this event occurs in the device history. | ||
| For Repeaters only, “Near Shutdown” status message now only shows when AGC >=20dB. We recommend adding 6dB manual attenuation when you see the “Near Shutdown” status message. Other wise, no need to add manual attenuation. | ||
| This will mean that installers will very rarely need to add manual attenuation anymore for V9 iRepeaters. | ||
| False uplink oscillations fixed. | ||
| Continous uplink alert now more reliable. | ||
| Rebal and Reboot synced to 12 midnight , local time. fixed bug | ||
| 25/6/2023 | 7.2.3.18 | Binary Difference messaging implemented. Very small message size. (40 BYTES per message) |
| Smart attenuation improved. | ||
| Max hold on LEDs to smoothen them out (slow decay). Max hold for UL and DL sent to platform. | ||
| New info message warnings on main LCD screen, popup on user touch of little (i). | ||
| BAND_ENABLE remotely enable / disable bands. | ||
| When 6th green LED power turns on, we are at maximum power, with just a little AGC occurring. | ||
| Feedback detection added to DL. More reliable. | ||
| 14/4/2023 | 7.2.1.11 | Improve display startup sequence. |
| 5/11/2022 | 7.2.1.8 | Reinstate missing fan control |
| Band UL percentage improved. Average over last X minutes, where X = message frequency. Status bar improved with new status message and colors. | ||
| Uplink duty-cycle reporting fix | ||
| Subtle upgrade indicator; DIFF message flag | ||
| iR4_v2 updated code, fix to agc code bug, OCS_COUNTDOWN = 10 seconds., installer code on concole removed on startup. | ||
| 4/12/2022 | 7.2.0.70 | SW counter now working. The WDT is now counting up properly. |
| LCD 180DEG bug fixed. Restore FW button removed, band-plan chaged removed for all excvept DEV, persisten icons in menu fixed. | ||
| GPS report bug fixed. Random crash happening bug due to GPS fixed. Issue with temperature variable saving to eeprom fixed. | ||
| Binary Message implemented. | ||
| 13/4/2022 | 7.1.1.63 | Removed clamp from CombinerAmps. We add oscillation tokens but not extra clamp attenuation. |
| 4xTap bottom left of main screen rotates LCD. No rebalance for Combiners | ||
| Show group atten to Installer and up. | ||
| Slower AGC attenation release on Combiners | ||